Zhl16b does not handle multilevel oc/ccr changing right.
Reported by: | eskil | Owned by: | eskil |
---|---|---|---|
Priority: | blocker | Milestone: | Version 0.9.2 |
Component: | ZHL16 | Version: | 0.9 |
Severity: | Must Have | Keywords: | |
Cc: | Fixed in Version: | 0.9.2 |
Description
See Q&A thread on CCR bailout.
Zhl16b does not properly switch gas, plus creates stop that are just slightly off the step interval (possibly just the UI rounding it ?).
- 100fsw/30min, air@1.3
- 100fsw/1 min, air
Should yield two levels, with the second being air on OC, but it stays on CCR instead.