Ticket #9 (closed defect: fixed)

Opened 16 years ago

Last modified 16 years ago

Zhl16b does not handle multilevel oc/ccr changing right.

Reported by: eskil Owned by: eskil
Priority: blocker Milestone: Version 0.9.2
Component: ZHL16 Version: 0.9
Severity: Must Have Keywords:
Cc: Fixed in Version: 0.9.2

Description

See Q&A thread on CCR bailout.

Zhl16b does not properly switch gas, plus creates stop that are just slightly off the step interval (possibly just the UI rounding it ?).

  • 100fsw/30min, air@1.3
  • 100fsw/1 min, air

Should yield two levels, with the second being air on OC, but it stays on CCR instead.

Attachments

zhl16-ccr-levels.jpg Download (36.5 KB) - added by eskil 16 years ago.
The levels
zhl16-ccr-profile.jpg Download (44.5 KB) - added by eskil 16 years ago.
The resulting incorrect plan.

Change History

Changed 16 years ago by eskil

The levels

Changed 16 years ago by eskil

The resulting incorrect plan.

Changed 16 years ago by eskil

  • status changed from new to accepted

Changed 16 years ago by eskil

  • summary changed from Zhl16b does not handle multileve oc/ccr changing right. to Zhl16b does not handle multilevel oc/ccr changing right.

Changed 16 years ago by eskil

Fixed in 647.

Changed 16 years ago by eskil

  • milestone changed from Version 1.0 to Version 0.9.2

Changed 16 years ago by eskil

  • status changed from accepted to closed
  • resolution set to fixed

Changed 16 years ago by eskil

  • fixed_in_version set to 0.9.2
Note: See TracTickets for help on using tickets.